AP7922B Rack PDU, Switched, 2U, 32A, 230V, (16)C13


Compare Support

Availability

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependent on that unit will function properly.

Load indicator LED
Indicates overload and warning conditions based on the user-defined alarm thresholds. Alerts users of potential overloaded circuits.

Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video, and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. It eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Network Management Capabilities
Full-featured network management interfaces provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage rack PDUs from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Local Current Monitoring Display
The aggregate current draw per rack PDU is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip. (Available on designated SKUs only)

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems. (Note: Only available on units with the current monitoring capabilities. Please see SKU specifications for availability)

Marketing Features

Power Delays
Allows users to configure the sequence in which power is turned on or off for each outlet. This helps avoid in-rushes at start-up, which can cause overloaded circuits and dropped loads. Sequencing also allows users to predetermine which piece of equipment is turned on first so other equipment dependent on that unit will function properly.

Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits. Network and visual alarms inform the user of possible problems.

Remote Management Capabilities
Full-featured network management interfaces provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.

Remote Individual Outlet Control
Remotely manage outlets so users can turn outlets off that are not in use (prevent overloads) or recycle power to locked-up equipment (minimize costly downtime and avoid travel time to equipment).

Local Current Monitoring Display
The aggregate current draw per power distribution unit is displayed on the unit via a digital display. The local digital display helps installers avoid overloaded circuits by providing a visible warning when the current draw is close to the maximum amperage draw of the strip.

Agility

Single input power source
Supply power from one branch whip to multiple pieces of equipment, conveniently powering rack-mount equipment. Saves time and money during installation by using one branch whip and standard connections.

Wide range of input and output connections
The product family includes a variety of input and output connections to distribute 120V, 208V, or 230V power to multiple outlets. Various inputs and outputs allow users to adapt to varying power requirements. APC offers units that bring up to 14.4kW using a single branch whip.

Rack-Mountable
Includes horizontal, vertical, and toolless-mount varieties. Puts power where it is needed most – in the racks near the equipment.

Ports & interfaces
AC outlets quantity
16 AC outlet(s)
Power plug
IEC309
AC outlet types
C13 coupler
Design
PDU types
Metered, Switched
Type
Single-phase
Rack capacity
2U
Mounting
Horizontal
Product colour
Black
Power
Nominal input voltage
200-230 V
AC input frequency
50 – 60 Hz
Maximum current
32 A
Nominal output voltage
230 V
Load capacity
7360 VA
Maximum input current per phase
32 A
Maximum total current draw per phase
32 A
Maximum power
7360 W
Operational conditions
Operating temperature (T-T)
0 – 45 °C
Storage temperature (T-T)
-25 – 65 °C
Operating relative humidity (H-H)
0 – 95 %
Storage relative humidity (H-H)
0 – 95 %
Operating altitude
0 – 3000 m
Non-operating altitude
0 – 15000 m
Features
Cable length
3.05 m
Certification
CE, EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, GOST, IRAM, MIC, VDE, REACH
Management features
Monitoring
Current, Power, Voltage
Outlet control
Lock-out, Recycle, Turn off, Turn on
Weight & dimensions
Dimensions (WxDxH)
445 x 114 x 89 mm
Weight
4.5 kg
Packaging data
Package dimensions (WxDxH)
508 x 368 x 140 mm
Package weight
6.55 kg
Technical details
Sustainability certificates
RoHS
Packaging content
Packaging content
Documentation CD, Installation Guide, Rack Mounting Brackets