Mercury Online double-conversion UPS defends mission-critical servers, networking or telecommunications equipment from blackouts, brownouts, voltage fluctuations and surges.

High frequency and double conversion on-line technology
Fully digitized microprocessor control
Wide input voltage range
LCD display
UPS startup without battery
Cold start
Advanced battery management
Automatic battery charge in UPS off mode
Lightning and surge protection
Short circuit and overload protection
Fan speed auto control when loads vary
Network/Fax/Modem surge protection
Optional extension battery pack
Battery voltage display
Load capacity display
EMI/RFI noise filter
Smart RS232 communication with monitoring software
Optional SNMP card slot
EPO function(optional)
Input L and N reversed alarm function

Capacity 3KVA / 2400W
Phase Single Phase
Input voltage 115VAC(±5) ~ 295VAC(±5) if load ≤ 70%; 160VAC(±5) ~ 295VAC(±5) if load ≥ 70%
Frequency 46 ~ 54(50Hz)±0.5Hz; 56 ~ 64(60Hz)±0.5Hz auto-sensing
Input power factor ≥ 0.97
Output voltage 220/230VAC ± 2%
Frequency 50Hz / 60Hz ± 0.2%
THD < 3% (linear load); < 5% (non linear load)
Overload capability > 110%, 30s turn to bypass mode; > 150%, 300ms turn to bypass mode
Crest factor 3:1 (max)
AC Mode: 10 cycles, when voltage lower than rated 30%,
and inrush current higher than rated 70%,
turn off the inverter, no transfer to bypass,
give alarm battery Mode: 10 cycles, when voltage lower than rated 30%
and inrush current higher than rated 70%,
turn off the inverter, give an alarm bypass Mode: Input fuse blew or break action
Waveform Pure sine wave
Transfer time 0ms between AC mode & Bypass mode
4ms (typical 2.5ms) between Inverter mode & Bypass mode
Efficiency ≥ 87%
Model 12V sealed lead acid maintenance-free
Battery 8x 12V / 7AH
DC voltage 96VDC
Back-up 12min (half load); 5min (full load)
Recharge time 8hours ~ 90% capacity
Charge current 1A(standard unit);6A(long-time unit)
Communication interface RS232 ; SNMP (optional)
LED indication Load or battery capacity
Noise level < 45dB
Temperature 0 ~ 40ËšC
Humidity 0% ~ 95% (non-condensing)
Altitude < 1500m
Storage temperature -25 ~ 55ËšC
Standard unit (net/gross) 28/30.5 kg
Long-time unit (net/gross) 11/13 kg
Dimension (WxDxH)mm 190 x 468 x 339
Packing(WxDxH)mm 275 x 563 x 446