HF Series is a new hybrid solar charge inverter, which integrates PV charge &Grid(Generator) charge with AC sine wave output.
Adopting DPS control algorithm, getting higher response speed, higher reliability, and higher industrial standard.
HF Series is a new hybrid solar charge inverter, which integrates PV charge &Grid(Generator) charge with AC sine wave output.
Adopting DPS control algorithm, getting higher response speed, higher reliability, and higher industrial standard.
Rated Power: 3000Watts
Peak Power: 6000VA
Loaded motor capability: 2HP
Max Solar: 1400Watts
Max Solar Current: 60A
PV input : 100V
Max AC Charging: 80A
₦517,000.00
Compare SupportModels | HF2420S60-100 | HF2430S60-100 |
AC mode | ||
Rated input voltage | 220/230Vac | |
Input voltage range | (170Vac~280Vac) ±2%;(90Vac-280Vac)±2% | |
Frequency | 50Hz/ 60Hz (Auto detection) | |
Frequency Range | 47±0.3Hz ~ 55±0.3Hz (50Hz)/57±0.3Hz ~ 65±0.3Hz (60Hz); | |
Overload/short circuit protection | Circuit breaker | |
Efficiency | >95% | |
Conversion time (bypass and inverter) | 10ms (typical) | |
AC reverse protection | Available | |
Maximum bypass overload current | 30A | |
Inverter mode | ||
Output voltage waveform | Pure sine wave | |
Rated output power (VA) | 2000 | 3000 |
Rated output power (W) | 2000 | 3000 |
Power factor | 1 | |
Rated output voltage (Vac) | 230Vac | |
Output voltage error | ±5% | |
Output frequency range (Hz) | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | |
Efficiency | >92% | |
Overload protection |
(102% < load<125%) ±10%: report error and turn off
the output after5 minutes; (125% < load < 150%) ± 10%: report error and turn off the output after 10 seconds; Load >150% ±10%: report error and turn off the output after 5 seconds; |
|
Peak power | 4000 | 6000 |
Loaded motor capability | 1HP | 2HP |
Output short circuit protection | Circuit breaker | |
Bypass breaker specifications | 30A | |
Rated battery input voltage | 24V (Minimum starting voltage 22V) | |
Battery voltage range | (20.0Vdc~33Vdc ± 0.6Vdc (Undervoltage alarm/shutdown voltage/overvoltage alarm /overvoltage recovery settable on LCD screen) | |
Power saving mode
AC charging |
Load ≤25W | |
Battery type | Lead acid or lithium battery | |
Maximum charge current | 60A | 80A |
Charge current error | ± 5Adc | |
Charge voltage range | 18.0Vdc~33Vdc | |
Short circuit protection | Circuit breaker and blown fuse | |
Circuit breaker specifications | 30A | |
Overcharge protection | Alarm and turn off charging after 1 minute | |
PV charging | ||
Maximum PV open circuit voltage | 100Vdc | |
PV operating voltage range | 30-100Vdc | |
MPPT voltage range | 30-95Vdc | |
Battery voltage range | 18-33Vdc | |
Maximum output power | 1400W | |
PV charging current range (can be set) | 0-60A | |
Charging short circuit protection | Blown fuse | |
Wiring protection
Certified specifications |
Reverse polarity protection | |
Certification | CE(IEC/EN62109-1,-2)、ROHS2.0 | |
EMC certification level | EN61000 | |
Operating temperature range | -15°C to 55°C | |
Storage temperature range | -25°C ~ 60°C | |
Humidity range | 5% to 95% (Conformal coating protection) | |
Noise | ≤60dB | |
Heat dissipation | Forced air cooling, variable speed of fan | |
Communication interface | USB/RS485(Bluetooth/WiFi/GPRS)/Dry node control | |
Size (L*W*D) | 378mm*280mm*103mm | |
Weight (kg) | 6.2 |
There are no reviews yet.